Metadata
- Source
- FLUID-6652
- Type
- Bug
- Priority
- Major
- Status
- Open
- Resolution
- N/A
- Assignee
- N/A
- Reporter
- Justin Obara
- Created
2021-07-06T08:08:41.243-0400 - Updated
2021-07-06T08:09:45.042-0400 - Versions
-
- 3.0
- Fixed Versions
- N/A
- Component
-
- Prefs Framework
Description
Steps to reproduce:
- Open the conditional adjusters - single panel example
- Open the prefs editor
- Using the keyboard, place focus on the "Magnification" switch and activate it
- Using the keyboard press the "tab" key.
- Notice that focus starts from the "Speak Text" switch instead of from the "Magnification" switch.
Comments
-
Justin Obara commented
2021-07-06T08:09:45.042-0400 This is likely due to the entire panel being re-rendered when the switch is activated; which causes the focus position to be lost.